Air speed moves the chips, not just the air
Dust collection works when air moves fast enough through the duct to keep chips suspended: about 4000 feet per minute in horizontal runs. CFM capacity is duct area times that velocity, which is why a 4 in duct tops out near 350 CFM no matter how large the collector is. Enter a duct or port diameter and the calculator returns the CFM it can carry.
The machine table is a starting point
The reference table lists approximate minimum CFM demand for common machines at their factory port sizes. Published figures differ between sources because hoods, gates and pickup design change the real requirement; machines that throw chips, like planers and drum sanders, want more than saws that drop dust politely.
Duct losses are real
Every foot of flexible hose, every 90 degree elbow and every blast gate eats static pressure and capacity. The computed CFM is the ceiling the duct allows at transport velocity, not what the collector delivers at the tool. Runs with many bends belong to a static pressure worksheet, which this tool does not model.